Skip to main content

QUESTION 06 06

Estimation and designFoundation12 min suggested

How many refill taps would you need?

You are planning drinking-water refill points for a fictional three-hour event attended by 300 people. No demand measurements are available yet. Choose and justify a plausible range for water collected per person per hour as a planning assumption. Each tap can deliver 6 litres per minute while running, but assume it is running only half the time because people change bottles. For the peak-demand calculation, suppose 25% of the event’s total water is collected during one ten-minute break. This is an estimation exercise, not guidance on how much individuals should drink.

Talk it through

  1. Estimate total water demand. State a central assumption and show how a lower and upper assumption change your answer.

  2. Convert your central volume into cubic metres and estimate its mass, using a water density of 1,000 kg/m³.

  3. Estimate the number of taps needed for the ten-minute peak. Why might a design based on the three-hour average give the wrong answer?

Notes save automatically on this device. Clearing browser data removes them.

A nudge in the right direction

0 / 3
COMPARE YOUR REASONINGExplore a worked discussion
01

One illustrative assumption is 0.6 litres collected per person per hour, giving 300 × 3 × 0.6 = 540 litres. A range of 0.4 to 0.8 gives 360 to 720 litres. These are assumptions, not measured consumption rates. Weather, activity, attendance and whether people bring filled bottles could change demand; several justified estimates are possible.

02

The central volume is 540/1,000 = 0.54 m³. Its water mass is 0.54 × 1,000 = 540 kg, excluding the container. The lower and upper estimates correspond to 360 and 720 kg. This makes clear that storing the supply is a substantial physical task, even when the volume sounds modest.

03

For the central case, the ten-minute break uses 0.25 × 540 = 135 litres, requiring 13.5 litres per minute. At an effective 3 litres per minute per tap, 13.5/3 = 4.5, so at least five taps are needed under this capacity model. The low and high estimates require three and six taps respectively.

04

The event-wide average is only 540/180 = 3 litres per minute, apparently one tap’s effective capacity. That hides the peak. Even five taps do not guarantee short queues if everyone arrives together or the shared pipe cannot supply them. Measure bottle-change times and demand on a small trial, then revise the assumptions and consider a capacity margin.

THE INTERVIEWER TAKES IT FURTHER

Now change the question.

Someone suggests adding more taps to the same pipe. What would you check before agreeing?

Discuss the follow-up

The stated 6 litres per minute per tap may not hold when several taps run together. Check the total supply flow and pressure under simultaneous use, along with the refill pattern. Extra outlets help only if the common supply and layout can support them; testing the full arrangement is more useful than timing one isolated tap.

Before you move on

Use these prompts to reflect on your attempt.

You can come back to this question any time.